WM-Y150 unit technical data
WM-Y150 Unit Technical Data
| Output Power (kVA) | 187/200 |
|||||||
| Output Power (kW) |
150/160 |
|||||||
| Power Factor |
0.8 (Lagging) |
|||||||
| Frequency (HZ) |
50 |
|||||||
| Output Voltage (V) |
400/230 |
|||||||
| Maximum (Continuous/Standby) Output Current (A) |
270/288 |
|||||||
| Unit Dimensions (Length × Width × Height) (mm) |
2800×1000×1450 |
|||||||
| Unit Net Weight (kg) |
1800 |
|||||||
| Diesel Engine |
|
|||||||
| Manufacturer |
Yuchai Group |
|||||||
| Model |
YC6A245-D30 |
Rated Speed (RPM) |
1500 |
|||||
| Number of Cylinders |
6 |
Output Power (kW) |
181 |
|||||
| Cylinder Arrangement |
L |
Fuel Specifications and Grade |
China 0# (Light Diesel) |
|||||
| Bore/Stroke (mm) |
108/132 |
Noise dB(A) |
98 |
|||||
| Total Cylinder Capacity (L) |
7.25 |
Minimum Fuel Consumption Rate (g/kwh) |
≤200 |
|||||
| Compression Ratio |
17.5:1 |
Lubricating Oil Specifications and Grade |
API-CD Grade and Above |
|||||
| Intake Method |
Turbocharged Intercooled |
Total Lubricating Oil Capacity (L) |
22 |
|||||
| Speed Control Method |
Electronic Controlled High-Pressure Common Rail |
Lubricating Oil Consumption (L/h) |
0.202 |
|||||
| Starting Method |
Electric Start |
Normal Operating Temperature of Lubricating Oil (℃) |
125 |
|||||
| Allowable Maximum Back Pressure (kPa) |
10 |
Maximum Exhaust Temperature (℃) |
499 |
|||||
| Cooling Method |
Closed-Cycle Water Cooling |
Air Consumption (m3/min) |
4.4 |
|||||
| Total Cooling Water Capacity (L) |
27 |
Intake Airflow (m3/min) |
6.15 |
|||||
| Normal Operating Temperature of Cooling Water (℃) |
82-93 |
Total Dry Weight of Diesel Engine (kg) |
825 |
|||||
| Cooling Water Flow Rate (L/sec) |
2.3 |
Overall Dimensions Including Water Tank (mm) |
1740×960×1160 |
|||||
| Generator |
|
|||||||
| Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
||||||
| Model |
WM150 |
Excitation Method |
Brushless Self-Excited (Optional PMG) |
|||||
| Voltage Adjustment Range |
≥±5% |
Steady-State Voltage Regulation Rate |
≤±1.0% |
|||||
| Temperature Rise |
H |
Voltage Control Method |
AVR |
|||||
| Insulation Class |
H |
Overload Capacity |
1.5 times for 2 minutes |
|||||
| Protection Class |
IP22 |
Short Circuit Capacity |
3 times for 10 seconds |
|||||
| Efficiency |
92.4% |
Cooling Method |
Self-Cooling |
|||||
| Telephone Interference Coefficient |
THF<2%, TIF<50 |
Rotor Type |
Salient-Pole Type |
|||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12