WM-Y120 unit technical data
| Output Power (kVA) |
150/175 |
|||||||
|
Output Power (kW) |
120/140 |
|||||||
|
Power Factor |
0.8 (Lagging) |
|||||||
|
Output Voltage (V) |
400/230 |
|||||||
|
Maximum (Continuous/Standby) Output Current (A) |
216/252 |
|||||||
|
Unit Dimensions (Length × Width × Height) (mm) |
2800×1000×1450 |
|||||||
|
Net Weight of Unit (kg) |
1600 |
|||||||
|
Diesel Engine |
|
|||||||
|
Manufacturer |
Yuchai Group |
|||||||
|
Model |
YC6A205-D30 |
Rated Speed (RPM) |
1500 |
|||||
|
Number of Cylinders |
6 |
Output Power (kW) |
152 |
|||||
|
Cylinder Arrangement |
L |
Fuel Specifications and Grade |
China 0# (Light Diesel) |
|||||
|
Bore/Stroke (mm) |
108/132 |
Noise dB(A) |
98 |
|||||
|
Total Cylinder Capacity (L) |
7.25 |
Minimum Fuel Consumption Rate (g/kwh) |
≤200 |
|||||
|
Compression Ratio |
17.5:1 |
Lubricating Oil Specifications and Grade |
API-CD Grade and Above |
|||||
|
Intake Method |
Turbocharged Intercooled |
Total Lubricating Oil Capacity (L) |
22 |
|||||
|
Speed Control Method |
Electronic Controlled High-Pressure Common Rail |
Lubricating Oil Consumption (L/h) |
0.058 |
|||||
|
Starting Method |
Electric Start |
Normal Operating Temperature of Lubricating Oil (℃) |
105 |
|||||
|
Allowable Maximum Back Pressure (kPa) |
10 |
Maximum Exhaust Temperature (℃) |
585 |
|||||
|
Cooling Method |
Closed-Cycle Water Cooling |
Air Consumption (m3/min) |
4.4 |
|||||
|
Total Cooling Water Capacity (L) |
27 |
Intake Airflow (m3/min) |
6.15 |
|||||
|
Normal Operating Temperature of Cooling Water (℃) |
70-80 |
Total Dry Weight of Diesel Engine (kg) |
825 |
|||||
|
Cooling Water Flow Rate (L/sec) |
2.33 |
Overall Dimensions Including Water Tank (mm) |
1740×960×1160 |
|||||
|
Generator |
|
|||||||
|
Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|||||||
|
Model |
WM128 |
Excitation Method |
Brushless Self-Excited (PMG Optional) |
|||||
|
Voltage Adjustment Range |
≥±5% |
Steady-State Voltage Regulation Rate |
≤±1.0% |
|||||
|
Temperature Rise |
H |
Voltage Control Method |
AVR |
|||||
|
Insulation Class |
H |
Overload Capacity |
1.5 times for 2 minutes |
|||||
|
Protection Class |
IP22 |
Short Circuit Capacity |
3 times for 10 seconds |
|||||
|
Efficiency |
88.9% |
Cooling Method |
Self-Cooling |
|||||
|
Telephone Interference Coefficient |
THF<2%, TIF<50 |
Rotor Type |
Salient-Pole Type |
|||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.