WM-Y80 unit technical data
WM-Y80 Genset Technical Data
| Output Capacity (kVA) | 100/ 112.5 |
||||||
| Output Power (kW) |
80/ 90 |
||||||
| Power Factor |
0.8 (Lagging) |
||||||
| Frequency (Hz) |
50 |
||||||
| Output Voltage (V) |
400 / 230 |
||||||
| Maximum (Continuous/Standby) Output Current (A) |
144/162 |
||||||
| Genset Dimensions (L×W×H) (mm) |
2100×860×1400 |
||||||
| Genset Net Weight (kg) |
1300 |
||||||
| Diesel Engine |
|||||||
| Manufacturer |
Yuchai Group |
||||||
| Model |
YC4D140-D30 |
Rated Speed (RPM) |
1500 |
||||
| Number of Cylinders |
4 |
Maximum Output Power (kW) |
: 105 |
||||
| Cylinder Arrangement |
L |
Fuel Specifications and Grade |
China 0# (Light Diesel) |
||||
| Bore/Stroke (mm) |
108/115 |
Minimum Fuel Consumption Rate (g/kWh) |
≤205 |
||||
| Total Cylinder Capacity (L) |
4.21 |
Lubricant Specifications and Grade |
API-CF Grade and Above |
||||
| Compression Ratio |
16.7:1 |
Total Lubricant Capacity (L) |
13 |
||||
| Intake Method |
Turbocharged and Intercooled |
Maximum Lubricant Temperature (°C) |
121 |
||||
| Speed Control Method |
Electronic Controlled High-Pressure Common Rail |
Maximum Exhaust Temperature (°C) |
: 571 |
||||
| Thermostat Adjustment Temperature Range (°C) |
82-93 |
Air Consumption (m3/min) |
4.4 |
||||
| Allowable Maximum Back Pressure (KPa) |
6.0 |
Intake Airflow (m3/min) |
6.15 |
||||
| Cooling Method |
Closed-Cycle Water Cooling |
Total Dry Weight of Diesel Engine (kg) |
525 |
||||
| Coolant Capacity (L) |
19 |
Dimensions Including Water Tank (mm) |
1403×740×1003 |
||||
| Generator |
|||||||
| Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
||||||
| Model |
WM80 |
Excitation Method |
Brushless Self-Excited (Optional Auxiliary Winding) |
||||
| Voltage Regulation Range |
≥±5% |
Steady-State Voltage Regulation Rate |
≤±1.0% |
||||
| Temperature Rise |
H |
Voltage Control Method |
AVR |
||||
| Insulation Class |
H |
Overload Capacity |
1.5 times for 2 minutes |
||||
| Protection Class |
IP22 |
Short Circuit Capacity |
3 times for 10 seconds |
||||
| Efficiency |
88.1% |
Cooling Method |
Self-Cooling |
||||
| Telephone Interference Coefficient |
THF<2%, TIF<50 |
Rotor Type |
Salient-Pole Type |
||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12