WM-Y70 unit technical data
YCM80D30 Unit Technical Data
Output Power (kVA) |
: 87.5/100 |
|||||||
| Output Power (kW) |
: 70/80 |
|||||||
| Power Factor |
: 0.8 (Lagging) |
|||||||
| Output Voltage (V) |
: 400/230 |
|||||||
| Maximum (Continuous/Standby) Output Current (A) |
: 126/144 |
|||||||
| Unit Dimensions (Length × Width × Height) (mm) |
: 2100 × 860 × 1400 |
|||||||
| Unit Net Weight (kg) |
: 1260 |
|||||||
| Diesel Engine |
|
|||||||
| Manufacturer |
: Yuchai Group |
|||||||
| Model |
: YC4D120-D30 |
Rated Speed (RPM) |
: 1500 |
|||||
| Number of Cylinders |
: 4 |
Output Power (kW) |
: 88 |
|||||
| Cylinder Arrangement |
: L |
Fuel Specifications and Grade |
: China 0# (Light Diesel) |
|||||
| Bore/Stroke (mm) |
: 108/115 |
Noise dB(A) |
: 96 |
|||||
| Total Cylinder Displacement (L) |
: 4.21 |
Minimum Fuel Consumption Rate (g/kwh) |
: ≤205 |
|||||
| Compression Ratio |
: 16.7:1 |
Lubricating Oil Specifications and Grade |
: API-CD Grade and Above |
|||||
| Intake Method |
: Turbocharged Intercooled |
Total Lubricating Oil Capacity (L) |
: 13 |
|||||
| Speed Control Method |
: Electronic Controlled High-Pressure Common Rail |
Lubricating Oil Consumption (L/h) |
: 0.08 |
|||||
| Starting Method |
: Electric Start |
Normal Operating Temperature of Lubricating Oil (℃) |
: 125 |
|||||
| Maximum Allowable Back Pressure (kPa) |
: 10.3 |
Maximum Exhaust Temperature (℃) |
: 571 |
|||||
| Cooling Method |
: Closed-Cycle Water Cooling |
Air Consumption (m3/min) |
: 4.4 |
|||||
| Total Cooling Water Capacity (L) |
: 19 |
Intake Airflow (m3/min) |
: 6.15 |
|||||
| Normal Operating Temperature of Cooling Water (℃) |
: 82-93 |
Total Dry Weight of Diesel Engine (kg) |
: 525 |
|||||
| Cooling Water Flow Rate (L/sec) |
: 1.4 |
Overall Dimensions Including Water Tank (mm) |
: 1403 × 740 × 1003 |
|||||
| Generator |
|
|||||||
| Manufacturer |
: Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
||||||
| Model |
: WM68 |
Excitation Method |
: Brushless Self-Excited (Optional Auxiliary Winding) |
|||||
| Voltage Regulation Range |
: ≥±5% |
Steady-State Voltage Regulation Rate |
: ≤±1.0% |
|||||
| Temperature Rise |
: H |
Voltage Control Method |
: AVR |
|||||
| Insulation Class |
: H |
Overload Capacity |
: 1.5 times for 2 minutes |
|||||
| Protection Class |
: IP22 |
Short Circuit Capacity |
: 3 times for 10 seconds |
|||||
| Efficiency |
: 87.9% |
Cooling Method |
: Self-Cooling |
|||||
| Telephone Interference Factor |
: THF<2%, TIF<50 |
Rotor Type |
: Salient-pole type |
|||||
Note: The above technical data is for reference only. Our company will not provide further notice if the technical parameters change due to various reasons.