WM-W90E unit technical data
| Output capacity (kVA) |
112.5/ 125 |
|||||
| Output power (kW) |
90/ 100 |
|||||
| Power factor |
0.8 (lagging) |
|||||
| Frequency (Hz) |
50 |
|||||
| Output voltage (V) |
400 / 230 |
|||||
| Maximum (long-term/standby) output current (A) |
162/ 180 |
|||||
| Unit dimensions (length × width × height) (mm) |
2200*820*1340 |
|||||
| Unit net weight (kg) |
1250 |
|||||
| Diesel engine |
||||||
| Manufacturer |
Weichai Power Co., Ltd. |
|||||
| Model |
WP4D108E200 |
Rated speed (RPM) |
1500 |
|||
| Number of cylinders |
4 |
Output power (kW) |
108/120 |
|||
| Cylinder arrangement |
L |
Fuel specifications and grade |
China 0# (light diesel) |
|||
| Bore/stroke (mm) |
105*130 |
Fuel consumption (L/h) |
70 |
|||
| Total cylinder capacity (L) |
14 |
Fuel consumption (g/kwh) |
≤198 |
|||
| Compression ratio |
18:1 |
Lubricating oil specifications and grade |
API-CD grade and above |
|||
| Intake method |
Turbocharged |
Total lubricating oil capacity (L) |
10 |
|||
| Speed control method |
Electronic control |
Lubricating oil consumption (L/h) |
0.26 |
|||
| Thermostat temperature control range (°C) |
Electric start DC12V |
Normal operating temperature of lubricating oil (°C) |
110 |
|||
| Allowable maximum back pressure (KPa) |
10 |
Maximum exhaust temperature (°C) |
550 |
|||
| Cooling method |
Closed-loop water cooling |
Intake air flow (m3/min) |
23.7/25.5 |
|||
| Coolant capacity (L) |
5.3 |
Exhaust gas flow (m3/min) |
62.8/67.5 |
|||
| Normal operating temperature of cooling water (°C) |
83-95 |
Air consumption (m3/min) |
39.1 |
|||
| Cooling water flow (L/sec) |
5.4 |
Radiator dimensions (length × width × height) (mm) |
310×995×1350 |
|||
| Generator |
||||||
| Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|||||
| Model |
WM 38BC |
Excitation method |
Brushless self-excited (PMG optional) |
|||
| Voltage adjustment range |
≥±5% |
Steady-state voltage regulation rate |
≤±1.0% |
|||
| Temperature rise |
H |
Voltage control method |
AVR |
|||
| Insulation class |
H |
Overload capacity |
1.5 times for 2 minutes |
|||
| Protection class |
IP22 |
Short-circuit capacity |
3 times for 10 seconds |
|||
| Efficiency |
92.65% |
Cooling method |
Self-cooled |
|||
| Telephone interference coefficient |
THF<2%, TIF<50 |
Rotor type |
Salient-pole type |
|||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.