CCM250S unit technical data
CCM 250S Unit Technical Data
Output Capacity (kVA) |
: 275 / 312.5 |
||||||
Output Power (kW) |
: 220 / 250 |
||||||
Power Factor |
: 0.8 (Lagging) |
||||||
Frequency (Hz) |
: 50 |
||||||
Output Voltage (V) |
: 400/230 |
||||||
Maximum (Continuous/Standby) Output Current (A) |
: 396 / 450 |
||||||
Unit Dimensions (Length × Width × Height) (mm) |
: 3100 × 1180 × 1760 |
||||||
Unit Net Weight (kg) |
: 2960 |
||||||
Diesel Engine |
|
||||||
Manufacturer |
: Chongqing Cummins (CCEC) |
||||||
Model |
: NTA855-G1A |
Rated Speed (RPM) |
: 1500 |
||||
Number of Cylinders |
: 6 |
Output Power (kW) |
: 291 |
||||
Cylinder Arrangement |
: L |
Fuel Specifications and Grade |
: China 0# (Light Diesel) |
||||
Bore/Stroke (mm) |
: 140*152 |
Fuel Consumption (L/h) |
: 58 |
||||
Total Cylinder Capacity (L) |
: 14 |
Fuel Consumption (g/kwh) |
: ≤202 |
||||
Compression Ratio |
: 14.5:1 |
Lubricating Oil Specifications and Grade |
: API-CD Grade and Above |
||||
Intake Method |
: Turbocharged |
Total Lubricating Oil Capacity (L) |
: 36.7 |
||||
Speed Control Method |
: Electronic Governor |
Lubricating Oil Consumption (L/h) |
: 0.24 |
||||
Starting Method |
: DC12V Electric Start |
Normal Operating Temperature of Lubricating Oil (℃) |
: 110 |
||||
Allowable Maximum Back Pressure (kPa) |
: 10 |
Maximum Exhaust Temperature (℃) |
: 550 |
||||
Cooling Method |
: Closed-Circuit Water Cooling |
Intake Airflow (m3/min) |
: 21.3/23.4 |
||||
Total Cooling Water Capacity (L) |
: 65 |
Exhaust Gas Flow (m3/min) |
: 55.3/60.8 |
||||
Normal Operating Temperature of Cooling Water (℃) |
: 83-95 |
Air Consumption (m3/min) |
: 34.2 |
||||
Cooling Water Flow (L/sec) |
: 5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
: 310 × 995 × 1350 |
||||
Generator |
|
||||||
Manufacturer |
: Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
|||||
Model |
: WM 31BH |
Excitation Method |
: Brushless Self-Excited (PMG Optional) |
||||
Voltage Regulation Range |
: ≥±5% |
Steady-State Voltage Regulation Rate |
: ≤±1.0% |
||||
Temperature Rise |
: H |
Voltage Control Method |
: AVR |
||||
Insulation Class |
: H |
Overload Capacity |
: 1.5 times for 2 minutes |
||||
Protection Class |
: IP22 |
Short Circuit Capacity |
: 3 times for 10 seconds |
||||
Efficiency |
: 92.47% |
Cooling Method |
: Self-cooling type |
||||
Telephone interference coefficient |
: THF < 2%, TIF < 50 |
Rotor type |
: Salient-pole type |
Note: The above technical data is for reference only. Our company will not provide further notice if the technical parameters change for various reasons.