WM-C300 unit technical data
WM-C300 Unit Technical Data
Output Capacity (kVA) | 337.5/ 375 | |||||
Output Power (kW) | 270/ 300 | |||||
Power Factor | 0.8 (Lagging) | |||||
Frequency (Hz) | 50 | |||||
Output Voltage (V) | 400 / 230 | |||||
Maximum (Long-term/Standby) Output Current (A) | 486/ 540 | |||||
Unit Dimensions (Length × Width × Height) (mm) | 3100×1030×1780 | |||||
Unit Net Weight (kg) | 3000 | |||||
Diesel Engine | ||||||
Manufacturer | Chongqing Cummins (CCEC) | |||||
Model | NTA855-G2A | Rated Speed (RPM) | 1500 | |||
Number of Cylinders | 6 | Output Power (kW) | 343 | |||
Cylinder Arrangement | L | Fuel Specifications and Grade | China 0# (Light Diesel) | |||
Bore/Stroke (mm) | 140/152 | Fuel Consumption (L/h) | 70 | |||
Total Cylinder Capacity (L) | 14 | Fuel Consumption (g/kwh) | ≤202 | |||
Compression Ratio | 14:1 | Lubricating Oil Specifications and Grade | API-CD Grade and Above | |||
Intake Method | Turbocharged | Total Lubricating Oil Capacity (L) | 38.6 | |||
Speed Control Method | Electronic Governor | Lubricating Oil Consumption (L/h) | 0.26 | |||
Thermostat Adjustment Temperature Range (℃) | DC12V Electric Start | Normal Operating Temperature of Lubricating Oil (℃) | 110 | |||
Allowable Maximum Back Pressure (KPa) | 10 | Maximum Exhaust Temperature (℃) | 550 | |||
Cooling Method | Closed-circuit Water Cooling | Intake Airflow (m3/min) | 23.7/25.5 | |||
Coolant Capacity (L) | 65 | Exhaust Gas Flow (m3/min) | 62.8/67.5 | |||
Normal Operating Temperature of Cooling Water (℃) | 83-95 | Air Consumption (m3/min) | 39.1 | |||
Cooling Water Flow (L/sec) | 5.4 | Radiator Dimensions (Length × Width × Height) (mm) | 310×995×1350 | |||
Generator | ||||||
Manufacturer | Jiangsu Weiming Power Generation Equipment Co., Ltd. | |||||
Model | WM 38BC | Excitation Method | Brushless Self-excited (PMG Optional) | |||
Voltage Adjustment Range | ≥±5% | Steady-state Voltage Regulation Rate | ≤±1.0% | |||
Temperature Rise | H | Voltage Control Method | AVR | |||
Insulation Class | H | Overload Capacity | 1.5 times for 2 minutes | |||
Protection Class | IP22 | Short-circuit Capacity | 3 times for 10 seconds | |||
Efficiency | 92.65% | Cooling Method | Self-cooled | |||
Telephone Interference Coefficient | THF<2%, TIF<50 | Rotor Type | Salient-pole |
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12