WM-C800 unit technical data
WM-C800 Unit Technical Data
Output Capacity (kVA) | 910 / 1000 | |||||||
Output Power (kW) | 728 / 800 | |||||||
Power Factor | 0.8 (Lagging) | |||||||
Frequency (Hz) | 50 | |||||||
Output Voltage (V) | 400 / 230 | |||||||
Maximum (Continuous/Standby) Output Current (A) | 1310 / 1440 | |||||||
Unit Dimensions (L×W×H) (mm) | 4450×1700×2360 | |||||||
Unit Net Weight (kg) | 8700 | |||||||
Diesel Engine | ||||||||
Manufacturer | Chongqing Cummins (CCEC) | |||||||
Model | KTA38-G2A | Rated Speed (RPM) | 1500 | |||||
Number of Cylinders | 12 | Output Power (kW) | 895 | |||||
Cylinder Arrangement | V | Fuel Specifications and Grade | China 0# (Light Diesel) | |||||
Bore/Stroke (mm) | 159/159 | Fuel Consumption (L/h) | 191 | |||||
Total Cylinder Capacity (L) | 37.8 | Fuel Consumption (g/kwh) | ≤202 | |||||
Compression Ratio | 14.5:1 | Lubricating Oil Specifications and Grade | API-CD Grade and Above | |||||
Intake Method | Turbocharged | Total Lubricating Oil Capacity (L) | 135 | |||||
Speed Control Method | Electronic Governor | Lubricating Oil Consumption (L/h) | 0.85 | |||||
Thermostat Adjustment Temperature Range (℃) | DC12V Electric Start | Normal Operating Temperature of Lubricating Oil (℃) | 110 | |||||
Allowable Maximum Back Pressure (KPa) | 10 | Maximum Exhaust Temperature (℃) | 550 | |||||
Cooling Method | Closed-Circuit Water Cooling | Intake Airflow (m3/min) | 62.5/67.6 | |||||
Coolant Capacity (L) | 244 | Exhaust Gas Flow (m3/min) | 176.2/193.5 | |||||
Normal Operating Temperature of Cooling Water (℃) | 83-95 | Air Consumption (m3/min) | 113.7 | |||||
Cooling Water Flow (L/sec) | 5.4 | Radiator Dimensions (L×W×H) (mm) | 410×1745×2025 | |||||
Generator | ||||||||
Manufacturer | Jiangsu Weiming Power Generation Equipment Co., Ltd. | |||||||
Model | MG40BHY Salt Mist and Moisture Proof Type | Excitation Method | Brushless Self-Excited (PMG Optional) | |||||
Voltage Adjustment Range | ≥±5% | Steady-State Voltage Regulation Rate | ≤±1.0% | |||||
Temperature Rise | H | Voltage Control Method | AVR | |||||
Insulation Class | H | Overload Capacity | 1.5 times for 2 minutes | |||||
Protection Class | IP22 | Short Circuit Capacity | 3 times for 10 seconds | |||||
Efficiency | 95.2% | Cooling Method | Self-Cooling | |||||
Telephone Interference Coefficient | THF<2%, TIF<50 | Rotor Type | Salient-Pole Type |
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12