WM-C1100 unit technical data
WM-C1100 Unit Technical Data
Output Capacity (kVA) | 1250 / 1375 | |||||||
Output Power (kW) | 1000 / 1100 | |||||||
Power Factor | 0.8 (Lagging) | |||||||
Frequency (Hz) | 50 | |||||||
Output Voltage (V) | 400 / 230 | |||||||
Maximum (Continuous/Standby) Output Current (A) | 1800 / 1980 | |||||||
Unit Dimensions (L×W×H) (mm) | 5200×2080×2500 | |||||||
Unit Net Weight (kg) | 11000 | |||||||
Diesel Engine | ||||||||
Manufacturer | Chongqing Cummins (CCEC) | |||||||
Model | KTA50-G3 | Rated Speed (RPM) | 1500 | |||||
Number of Cylinders | 16 | Output Power (kW) | 1227 | |||||
Cylinder Arrangement | V | Fuel Specifications and Grade | China 0# (Light Diesel) | |||||
Bore/Stroke (mm) | 159/159 | Fuel Consumption (L/h) | 274 | |||||
Total Cylinder Capacity (L) | 50.3 | Fuel Consumption (g/kwh) | ≤202 | |||||
Compression Ratio | 13.9:1 | Lubricating Oil Specifications and Grade | API-CD Grade and Above | |||||
Intake Method | Turbocharged | Total Lubricating Oil Capacity (L) | 177 | |||||
Speed Control Method | Electronic Governor | Lubricating Oil Consumption (L/h) | 1.37 | |||||
Thermostat Adjustment Temperature Range (℃) | DC12V Electric Start | Normal Operating Temperature of Lubricating Oil (℃) | 110 | |||||
Allowable Maximum Back Pressure (KPa) | 10 | Maximum Exhaust Temperature (℃) | 550 | |||||
Cooling Method | Closed-Circuit Water Cooling | Intake Airflow (m3/min) | 96.2 | |||||
Coolant Capacity (L) | 349 | Exhaust Airflow (m3/min) | 223.6 | |||||
Normal Operating Temperature of Cooling Water (℃) | 83-95 | Air Consumption (m3/min) | 131.4 | |||||
Cooling Water Flow Rate (L/sec) | 5.4 | Radiator Dimensions (L×W×H) (mm) | 410×1745×2025 | |||||
Generator | ||||||||
Manufacturer | Jiangsu Weiming Power Generation Equipment Co., Ltd. | |||||||
Model | WM 48OD | Excitation Method | Brushless Self-Excited (PMG Optional) | |||||
Voltage Adjustment Range | ≥±5% | Steady-State Voltage Regulation Rate | ≤±1.0% | |||||
Temperature Rise | H | Voltage Control Method | AVR | |||||
Insulation Class | H | Overload Capacity | 1.5 times for 2 minutes | |||||
Protection Class | IP22 | Short Circuit Capacity | 3 times for 10 seconds | |||||
Efficiency | 95.8% | Cooling Method | Self-Cooling | |||||
Telephone Interference Coefficient | THF<2%, TIF<50 | Rotor Type | Salient-Pole Type |
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.