WM-Y550 unit technical data
| Output Power (kVA) | 625/750 | |||||||
| Output Power (kW) | 550/600 | |||||||
| Power Factor | 0.8 (Lagging) | |||||||
| Frequency (HZ) | 50 | |||||||
| Output Voltage (V) | 400 / 230 | |||||||
| Maximum (Continuous/Standby) Output Current (A) | 990 / 1080 | |||||||
| Unit Dimensions (Length × Width × Height) (mm) | 3950×1400×2250 | |||||||
| Unit Net Weight (kg) | 4700 | |||||||
| Diesel Engine | ||||||||
| Manufacturer | Yuchai Group | |||||||
| Model | YC6TD900-D31 | Rated Speed (RPM) | 1500 | |||||
| Number of Cylinders | 6 | Output Power (kW) | 665 | |||||
| Cylinder Arrangement | L | Fuel Specifications and Grade | China 0# (Light Diesel) | |||||
| Bore/Stroke (mm) | 152/180 | Noise dB(A) | 100 | |||||
| Total Cylinder Displacement (L) | 19.6 | Minimum Fuel Consumption Rate (g/kwh) | ≤195 | |||||
| Compression Ratio | 14:1 | Lubricating Oil Specifications and Grade | API-CG4 and above | |||||
| Intake Method | Turbocharged Intercooled | Total Lubricating Oil Capacity (L) | 52 | |||||
| Speed Control Method | Electronic Controlled Unit Pump | Lubricating Oil Consumption (g/kwh) | 0.92 | |||||
| Starting Method | Electric Start | Normal Operating Temperature of Lubricating Oil (°C) | 105 | |||||
| Allowable Maximum Back Pressure (kPa) | 10 | Maximum Exhaust Temperature (°C) | 486 | |||||
| Cooling Method | Closed-circuit Water Cooling | Air Consumption (m3/min) | 4.4 | |||||
| Total Cooling Water Capacity (L) | 78 | Intake Airflow (m3/min) | 6.15 | |||||
| Normal Operating Temperature of Cooling Water (°C) | 86-98 | Total Dry Weight of Diesel Engine (kg) | 2670 | |||||
| Cooling Water Flow Rate (L/sec) | 10 | Overall Dimensions Including Water Tank (mm) | 2245×1456×1775 | |||||
| Generator | ||||||||
| Manufacturer | Jiangsu Weiming Power Equipment Co., Ltd. | |||||||
| Model | WM560 | Excitation Method | Brushless Self-excited (PMG Optional) | |||||
| Voltage Regulation Range | ≥±6% | Steady-state Voltage Regulation Rate | ≤±1.0% | |||||
| Temperature Rise | H | Voltage Control Method | AVR | |||||
| Insulation Class | H | Overload Capacity | 1.5 times for 2 minutes | |||||
| Protection Class | IP22 | Short Circuit Capacity | 3 times for 10 seconds | |||||
| Efficiency | 95% | Cooling Method | Self-cooled | |||||
| Telephone Interference Coefficient | THF<2%, TIF<50 | Rotor Type | Salient-pole | |||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12