WM-W30 unit technical data
Output capacity (kVA) |
37.5 / 41.25 |
||||||
Output power (kW) |
30 / 33 |
||||||
Power factor |
0.8 (lagging) |
||||||
Frequency (Hz) |
50 |
||||||
Output voltage (V) |
400/230 |
||||||
Maximum (long-term/standby) output current (A) |
54/ 59.4 |
||||||
Unit dimensions (length × width × height) (mm) |
1750*750*1350 |
||||||
Unit net weight (kg) |
620 |
||||||
Diesel engine |
|
||||||
Manufacturer |
Weichai Power Co., Ltd. |
||||||
Model |
TD226B-3D |
Rated speed (RPM) |
1500 |
||||
Number of cylinders |
3 |
Output power (kW) |
45/50 |
||||
Cylinder arrangement |
L |
Fuel specifications and grade |
China 0# (light diesel) |
||||
Bore/stroke (mm) |
105*120 |
Fuel consumption (L/h) |
58 |
||||
Total cylinder capacity (L) |
14 |
Fuel consumption (g/kwh) |
≤220 |
||||
Compression ratio |
15.5:1 |
Lubricating oil specifications and grade |
API-CD grade and above |
||||
Intake method |
Turbocharged |
Total lubricating oil capacity (L) |
7.25 |
||||
Speed control method |
Mechanical/electronic control |
Lubricating oil consumption (L/h) |
0.24 |
||||
Starting method |
Electric start DC12V |
Normal operating temperature of lubricating oil (℃) |
110 |
||||
Allowable maximum back pressure (kPa) |
10 |
Maximum exhaust temperature (℃) |
550 |
||||
Cooling method |
Closed-loop water cooling |
Intake air flow (m3/min) |
21.3/23.4 |
||||
Total cooling water capacity (L) |
15 |
Exhaust gas flow (m3/min) |
55.3/60.8 |
||||
Normal operating temperature of cooling water (℃) |
83-95 |
Air consumption (m3/min) |
34.2 |
||||
Cooling water flow (L/sec) |
5.4 |
Radiator dimensions (length × width × height) (mm) |
310×995×1350 |
||||
Generator |
|
||||||
Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
|||||
Model |
WM 31BH |
Excitation method |
Brushless self-excited (PMG optional) |
||||
Voltage adjustment range |
≥±5% |
Steady-state voltage regulation rate |
≤±1.0% |
||||
Temperature rise |
H |
Voltage control method |
AVR |
||||
Insulation class |
H |
Overload capacity |
1.5 times for 2 minutes |
||||
Protection class |
IP22 |
Short-circuit capacity |
3 times for 10 seconds |
||||
Efficiency |
92.47% |
Cooling method |
Self-cooled |
||||
Telephone interference coefficient |
THF<2%, TIF<50 |
Rotor type |
Salient-pole type |
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.