WM-KP275 unit technical data
Output capacity (kVA) |
343.75 |
|||||
|
Output power (kW) |
275 |
|||||
|
Power factor |
0.8 (lagging) |
|||||
|
Frequency (Hz) |
50 |
|||||
|
Output voltage (V) |
400 / 230 |
|||||
|
Maximum (long-term/standby) output current (A) |
495 |
|||||
|
Unit dimensions (length × width × height) (mm) |
2900*950*1600 |
|||||
|
Net weight of unit (kg) |
2350 |
|||||
|
Diesel engine |
||||||
|
Manufacturer |
Shanghai Kaisun Engine Co., Ltd. |
|||||
|
Model |
KP310 |
Rated speed (RPM) |
1500 |
|||
|
Number of cylinders |
6 |
Output power (kW) |
316 |
|||
|
Cylinder arrangement |
L |
Fuel specifications and grade |
China 0# (light diesel) |
|||
|
Bore/stroke (mm) |
135*155 |
Fuel consumption (L/h) |
70 |
|||
|
Total cylinder capacity (L) |
14 |
Fuel consumption (g/kwh) |
≤198 |
|||
|
Compression ratio |
18:1 |
Lubricating oil specifications and grade |
API-CD grade and above |
|||
|
Intake method |
Turbocharged |
Total lubricating oil capacity (L) |
10 |
|||
|
Speed control method |
Electronic control |
Lubricating oil consumption (L/h) |
0.26 |
|||
|
Thermostat adjustment temperature range (°C) |
Electric start DC12V |
Normal operating temperature of lubricating oil (°C) |
110 |
|||
|
Maximum allowable back pressure (KPa) |
10 |
Maximum exhaust temperature (°C) |
550 |
|||
|
Cooling method |
Closed-circuit water cooling |
Intake air flow (m3/min) |
23.7/25.5 |
|||
|
Coolant capacity (L) |
5.3 |
Exhaust gas flow (m3/min) |
62.8/67.5 |
|||
|
Normal operating temperature of cooling water (°C) |
83-95 |
Air consumption (m3/min) |
39.1 |
|||
|
Cooling water flow (L/sec) |
5.4 |
Radiator dimensions (length × width × height) (mm) |
310×995×1350 |
|||
|
Generator |
||||||
|
Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|||||
|
Model |
WM 38BC |
Excitation method |
Brushless self-excited (PMG optional) |
|||
|
Voltage adjustment range |
≥±5% |
Steady-state voltage regulation rate |
≤±1.0% |
|||
|
Temperature rise |
H |
Voltage control method |
AVR |
|||
|
Insulation class |
H |
Overload capacity |
1.5 times for 2 minutes |
|||
|
Protection class |
IP22 |
Short-circuit capacity |
3 times for 10 seconds |
|||
|
Efficiency |
92.65% |
Cooling method |
Self-cooled |
|||
|
Telephone interference coefficient |
THF<2%, TIF<50 |
Rotor type |
Salient-pole type |
|||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12