WM-KP180 unit technical data
WM-KP180 Unit Technical Data
| Output Capacity (kVA) |
225 |
||||||
| Output Power (kW) |
180 |
||||||
| Power Factor |
0.8 (Lagging) |
||||||
| Frequency (Hz) |
50 |
||||||
| Output Voltage (V) |
400/230 |
||||||
| Maximum (Long-term/Standby) Output Current (A) |
324 |
||||||
| Unit Dimensions (Length × Width × Height) (mm) |
2500*900*1400 |
||||||
| Unit Net Weight (kg) |
1600 |
||||||
| Diesel Engine |
|
||||||
| Manufacturer |
Shanghai Kaixun Engine Co., Ltd. |
||||||
| Model |
KP8D280D2 |
Rated Speed (RPM) |
1500 |
||||
| Number of Cylinders |
6 |
Output Power (kW) |
206 |
||||
| Cylinder Arrangement |
L |
Fuel Specifications and Grade |
China 0# (Light Diesel) |
||||
| Bore/Stroke (mm) |
105*120 |
Fuel Consumption (L/h) |
58 |
||||
| Total Cylinder Capacity (L) |
14 |
Fuel Consumption (g/kwh) |
≤198 |
||||
| Compression Ratio |
15.5:1 |
Lubricating Oil Specifications and Grade |
API-CD Grade and Above |
||||
| Intake Method |
Turbocharged |
Total Lubricating Oil Capacity (L) |
7.25 |
||||
| Speed Control Method |
Electronic Control |
Lubricating Oil Consumption (L/h) |
0.24 |
||||
| Starting Method |
Electric Start DC12V |
Normal Operating Temperature of Lubricating Oil (℃) |
110 |
||||
| Allowable Maximum Back Pressure (kPa) |
10 |
Maximum Exhaust Temperature (℃) |
550 |
||||
| Cooling Method |
Closed-circuit Water Cooling |
Intake Airflow (m3/min) |
21.3/23.4 |
||||
| Total Cooling Water Capacity (L) |
15 |
Exhaust Gas Flow (m3/min) |
55.3/60.8 |
||||
| Normal Operating Temperature of Cooling Water (℃) |
83-95 |
Air Consumption (m3/min) |
34.2 |
||||
| Cooling Water Flow (L/sec) |
5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
310×995×1350 |
||||
| Generator |
|
||||||
| Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
|||||
| Model |
WM 31BH |
Excitation Method |
Brushless Self-excited (PMG Optional) |
||||
| Voltage Adjustment Range |
≥±5% |
Steady-state Voltage Regulation Rate |
≤±1.0% |
||||
| Temperature Rise |
H |
Voltage Control Method |
AVR |
||||
| Insulation Class |
H |
Overload Capacity |
1.5 times for 2 minutes |
||||
| Protection Class |
IP22 |
Short-circuit Capacity |
3 times for 10 seconds |
||||
| Efficiency |
92.47% |
Cooling Method |
Self-cooled |
||||
| Telephone Interference Coefficient |
THF<2%, TIF<50 |
Rotor Type |
Salient-pole |
||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12