WMTC2000G unit technical data
WMTC2000G Unit Technical Data
| Output Capacity (kVA) | : 2250/2500 |
|||||||
| Output Power (kW) |
: 1800/2000 |
|||||||
| Power Factor |
: 0.8 (Lagging) |
|||||||
| Frequency (Hz) |
: 50 |
|||||||
| Output Voltage (V) |
: 400 / 230 |
|||||||
| Maximum (Long-term/Standby) Output Current (A) |
: 3240/3600 |
|||||||
| Unit Dimensions (Length × Width × Height) (mm) |
: 4500*2000*2600 |
|||||||
| Unit Net Weight (kg) |
: 7850 |
|||||||
| Diesel Engine |
|
|||||||
| Manufacturer |
: Nantong Diesel Engine Co., Ltd. |
|||||||
| Model |
: NGC16V3022 |
Rated Speed (RPM) |
: 1500 |
|||||
| Number of Cylinders |
: 16 |
Output Power (kW) |
: 2020/2222 |
|||||
| Cylinder Arrangement |
: V |
Fuel Specifications and Grade |
: China 0# (Light Diesel) |
|||||
| Bore/Stroke (mm) |
: 165*190 |
Fuel Consumption (L/h) |
: 289 |
|||||
| Total Cylinder Displacement (L) |
: 50.3 |
Fuel Consumption (g/kwh) |
: ≤196 |
|||||
| Compression Ratio |
: 15 :1 |
Lubricating Oil Specifications and Grade |
: API-CD Grade and Above |
|||||
| Intake Method |
: Turbocharged |
Total Lubricating Oil Capacity (L) |
: 240 |
|||||
| Speed Control Method |
: Electronic Control |
Lubricating Oil Consumption (L/h) |
: 1.44 |
|||||
| Thermostat Adjustment Temperature Range (℃) |
: DC12V Electric Start |
Lubricating Oil Normal Operating Temperature (℃) |
: 110 |
|||||
| Allowable Maximum Back Pressure (KPa) |
: 10 |
Maximum Exhaust Temperature (℃) |
: 550 |
|||||
| Cooling Method |
: Closed-circuit Water Cooling |
Intake Airflow (m3/min) |
: 62.5/67.6 |
|||||
| Coolant Capacity (L) |
: 528 |
Exhaust Gas Flow (m3/min) |
: 176.2/193.5 |
|||||
| Cooling Water Normal Operating Temperature (℃) |
: 83-95 |
Air Consumption (m3/min) |
: 113.7 |
|||||
| Cooling Water Flow (L/sec) |
: 5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
: 410×1745×2025 |
|||||
| Generator |
|
|||||||
| Manufacturer |
: Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|||||||
| Model |
: WM 48OE |
Excitation Method |
: Brushless Self-excited (PMG Optional) |
|||||
| Voltage Adjustment Range |
: ≥±5% |
Steady-state Voltage Regulation Rate |
: ≤±1.0% |
|||||
| Temperature Rise |
: H |
Voltage Control Method |
: AVR |
|||||
| Insulation Class |
: H |
Overload Capacity |
: 1.5 times for 2 minutes |
|||||
| Protection Class |
: IP22 |
Short-circuit Capacity |
: 3 times for 10 seconds |
|||||
| Efficiency |
: 95.6% |
Cooling Method |
: Self-cooling type |
|||||
| Telephone interference coefficient |
: THF <2%, TIF <50 |
Rotor type |
: Salient-pole type |
|||||
Note: The above technical data is for reference only. Our company will not provide further notice if the technical parameters change for various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12