WMTC900G unit technical data
WMTC900G Unit Technical Data
| Output Capacity (kVA) |
: 1000/1125 |
|||||||
| Output Power (kW) |
: 800/900 |
|||||||
| Power Factor |
: 0.8 (Lagging) |
|||||||
| Frequency (Hz) |
: 50 |
|||||||
| Output Voltage (V) |
: 400 / 230 |
|||||||
| Maximum (Long-term/Standby) Output Current (A) |
: 1440/1620 |
|||||||
| Unit Dimensions (Length × Width × Height) (mm) |
: 4500*2000*2600 |
|||||||
| Unit Net Weight (kg) |
: 5800 |
|||||||
| Diesel Engine |
|
|||||||
| Manufacturer |
: Nantong Diesel Engine Co., Ltd. |
|||||||
| Model |
: TCR890 |
Rated Speed (RPM) |
: 1500 |
|||||
| Number of Cylinders |
: 12 |
Output Power (kW) |
: 890/980 |
|||||
| Cylinder Arrangement |
: L |
Fuel Specifications and Grade |
: China 0# (Light Diesel) |
|||||
| Bore/Stroke (mm) |
: 138*165 |
Fuel Consumption (L/h) |
: 149.5 |
|||||
| Total Cylinder Capacity (L) |
: 18.9 |
Fuel Consumption (g/kwh) |
: ≤198 |
|||||
| Compression Ratio |
: 15:1 |
Lubricating Oil Specifications and Grade |
: API-CD Grade and Above |
|||||
| Intake Method |
: Turbocharged |
Total Lubricating Oil Capacity (L) |
: 122 |
|||||
| Speed Control Method |
: Electronic Control |
Lubricating Oil Consumption (L/h) |
: 0.56 |
|||||
| Thermostat Adjustment Temperature Range (℃) |
: DC12V Electric Start |
Normal Operating Temperature of Lubricating Oil (℃) |
: 110 |
|||||
| Allowable Maximum Back Pressure (KPa) |
: 10 |
Maximum Exhaust Temperature (℃) |
: 550 |
|||||
| Cooling Method |
: Closed-circuit Water Cooling |
Intake Airflow (m3/min) |
: 41.5/43.9 |
|||||
| Coolant Capacity (L) |
: 268 |
Exhaust Gas Flow (m3/min) |
: 111.3/119.5 |
|||||
| Normal Operating Temperature of Cooling Water (℃) |
: 83-95 |
Air Consumption (m3/min) |
: 69.8 |
|||||
| Cooling Water Flow (L/sec) |
: 5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
: 510×1550×1720 |
|||||
| Generator |
|
|||||||
| Manufacturer |
: Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|||||||
| Model |
: WM 38BJ |
Excitation Method |
: Brushless Self-excited (PMG Optional) |
|||||
| Voltage Regulation Range |
: ≥±5% |
Steady-state Voltage Regulation Rate |
: ≤±1.0% |
|||||
| Temperature Rise |
: H |
Voltage Control Method |
: AVR |
|||||
| Insulation Class |
: H |
Overload Capacity |
: 1.5 times for 2 minutes |
|||||
| Protection Class |
: IP22 |
Short-circuit Capacity |
: 3 times for 10 seconds |
|||||
| Efficiency |
: 94.33% |
Cooling Method |
: Self-cooling type |
|||||
| Telephone interference coefficient |
: THF <2%, TIF <50 |
Rotor type |
: Salient-pole type |
|||||
Note: The above technical data is for reference only. Our company will not provide further notice if the technical parameters change due to various reasons.