WMTC165G unit technical data
WMTC165G Unit Technical Data
| Output Capacity (kVA) |
: 187.5/206.25 |
||||||
| Output Power (kW) |
: 150/165 |
||||||
| Power Factor |
: 0.8 (Lagging) |
||||||
| Frequency (Hz) |
: 50 |
||||||
| Output Voltage (V) |
: 400/230 |
||||||
| Maximum (Continuous/Standby) Output Current (A) |
: 270/297 |
||||||
| Unit Dimensions (Length × Width × Height) (mm) |
: 2700*900*1700 |
||||||
| Unit Net Weight (kg) |
: 2000 |
||||||
| Diesel Engine |
|
||||||
| Manufacturer |
: Nantong Diesel Engine Co., Ltd. |
||||||
| Model |
: 6135AZD |
Rated Speed (RPM) |
: 1500 |
||||
| Number of Cylinders |
: 6 |
Output Power (kW) |
: 162/178 |
||||
| Cylinder Arrangement |
: L |
Fuel Specifications and Grade |
: China 0# (Light Diesel) |
||||
| Bore/Stroke (mm) |
: 135*150 |
Fuel Consumption (L/h) |
: 58 |
||||
| Total Cylinder Capacity (L) |
: 14 |
Fuel Consumption (g/kwh) |
: ≤202 |
||||
| Compression Ratio |
: 15.5:1 |
Lubricating Oil Specifications and Grade |
: API-CD Grade and Above |
||||
| Intake Method |
: Turbocharged |
Total Lubricating Oil Capacity (L) |
: 38 |
||||
| Speed Control Method |
: Mechanical/Electronic Control |
Lubricating Oil Consumption (L/h) |
: 0.24 |
||||
| Starting Method |
: Electric Start DC12V |
Normal Operating Temperature of Lubricating Oil (℃) |
: 110 |
||||
| Maximum Allowable Back Pressure (kPa) |
: 10 |
Maximum Exhaust Temperature (℃) |
: 550 |
||||
| Cooling Method |
: Closed-Cycle Water Cooling |
Intake Airflow (m3/min) |
: 21.3/23.4 |
||||
| Total Cooling Water Capacity (L) |
: 83.6 |
Exhaust Gas Flow (m3/min) |
: 55.3/60.8 |
||||
| Normal Operating Temperature of Cooling Water (℃) |
: 83-95 |
Air Consumption (m3/min) |
: 34.2 |
||||
| Cooling Water Flow (L/sec) |
: 5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
: 310×995×1350 |
||||
| Generator |
|
||||||
| Manufacturer |
: Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
|||||
| Model |
: WM 31BH |
Excitation Method |
: Brushless Self-Excited (PMG Optional) |
||||
| Voltage Adjustment Range |
: ≥±5% |
Steady-State Voltage Regulation |
: ≤±1.0% |
||||
| Temperature Rise |
: H |
Voltage Control Method |
: AVR |
||||
| Insulation Class |
: H |
Overload Capacity |
: 1.5 times for 2 minutes |
||||
| Protection Class |
: IP22 |
Short-Circuit Capacity |
: 3 times for 10 seconds |
||||
| Efficiency |
: 92.47% |
Cooling Method |
: Self-cooling type |
||||
| Telephone interference coefficient |
: THF<2%, TIF<50 |
Rotor type |
: Salient-pole type |
||||
Note: The above technical data is for reference only. Our company will not provide further notice if the technical parameters change due to various reasons.
Keywords:
Previous Page
Next Page
Previous Page:
Next Page:
Recommended News
What are the uses of diesel generator sets?
2020-12-26
The working principle of the generator set
2020-03-12
2020-03-12
Some precautions for using a generator
2020-03-12