WM-P70 unit technical data


Output capacity (kVA) 75/87.5
Output power (kW) 60/70
Power factor 0.8 (lagging)
Frequency (HZ) 50
Output voltage (V) 400 / 230
Maximum (long-term/standby) output current (A) 108/126
Unit dimensions (length × width × height) (mm) 1850*780*1200
Unit net weight (kg) 1150
Diesel engine  
Manufacturer Perkins Engines Company Limited (UK)
Model 1104A-44TG2 Rated speed (RPM) 1500
Number of cylinders 4 Output power (kW) 64/79
Cylinder arrangement L Fuel specifications and grade China 0# (light diesel)
Bore/stroke (mm) 105*127 Fuel consumption (L/h) 80.3
Total cylinder capacity (L) 14 Fuel consumption (g/kwh) ≤208
Compression ratio 18:1 Lubricating oil specifications and grade API-CD grade and above
Intake method Turbocharged Total lubricating oil capacity (L) 8
Speed control method Electronic speed control Lubricating oil consumption (L/h) 0.32
Thermostat adjustment temperature range (°C) Electric start DC12V Normal operating temperature of lubricating oil (°C) 110
Allowable maximum back pressure (KPa) 10 Maximum exhaust temperature (°C) 550
Cooling method Closed-circuit water cooling Intake air flow (m3/min) 23.7/25.5
Coolant capacity (L) 8 Exhaust gas flow (m3/min) 62.8/67.5
Normal operating temperature of cooling water (°C) 83-95 Air consumption (m3/min) 39.1
Cooling water flow (L/sec) 5.4 Radiator dimensions (length × width × height) (mm) 310×995×1350
Generator  
Manufacturer Jiangsu Weiming Power Generation Equipment Co., Ltd.
Model WM 38BD Excitation method Brushless self-excited (PMG optional)
Voltage adjustment range ≥±5% Steady-state voltage regulation rate ≤±1.0%
Temperature rise H Voltage control method AVR
Insulation class H Overload capacity 1.5 times for 2 minutes
Protection level IP22 Short-circuit capacity 3 times for 10 seconds
Efficiency 93.03% Cooling method Self-cooled
Telephone interference coefficient THF<2%, TIF<50 Rotor type Salient-pole type

Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.

Keywords: