WM-HD200 unit technical data
| Output Capacity (kVA) |
225/250 |
|||||||
| Output Power (kW) |
180/200 |
|||||||
| Power Factor |
0.8 (Lagging) |
|||||||
| Frequency (Hz) |
50 |
|||||||
| Output Voltage (V) |
400/230 |
|||||||
| Maximum (Continuous/Standby) Output Current (A) |
324/360 |
|||||||
| Unit Dimensions (Length × Width × Height) (mm) |
3000*1400*2100 |
|||||||
| Unit Net Weight (kg) |
2320 |
|||||||
| Diesel Engine |
|
|||||||
| Manufacturer |
Deutz |
|||||||
| Model |
BF6M1015-LA GA |
Rated Speed (RPM) |
1500 |
|||||
| Number of Cylinders |
6 |
Output Power (kW) |
208/231 |
|||||
| Cylinder Arrangement |
L |
Fuel Specifications and Grade |
China 0# (Light Diesel) |
|||||
| Bore/Stroke (mm) |
132*145 |
Fuel Consumption (L/h) |
53.4 |
|||||
| Total Cylinder Capacity (L) |
14 |
Fuel Consumption (g/kwh) |
≤196 |
|||||
| Compression Ratio |
17.5:1 |
Lubricating Oil Specifications and Grade |
API-CD Grade and Above |
|||||
| Intake Method |
Turbocharged |
Total Lubricating Oil Capacity (L) |
38 |
|||||
| Speed Control Method |
Electronic Governor |
Lubricating Oil Consumption (L/h) |
0.24 |
|||||
| Starting Method |
Electric Start DC12V |
Normal Operating Temperature of Lubricating Oil (℃) |
110 |
|||||
| Allowable Maximum Back Pressure (kPa) |
10.0 |
Maximum Exhaust Temperature (℃) |
550 |
|||||
| Cooling Method |
Closed-Circuit Water Cooling |
Intake Airflow (m3/min) |
19.44/21.06 |
|||||
| Total Cooling Water Capacity (L) |
65 |
Exhaust Gas Flow (m3/min) |
53.64/58.02 |
|||||
| Normal Operating Temperature of Cooling Water (℃) |
83-95 |
Air Consumption (m3/min) |
34.2 |
|||||
| Cooling Water Flow (L/sec) |
5.4 |
Radiator Dimensions (Length × Width × Height) (mm) |
310×995×1350 |
|||||
| Generator |
|
|||||||
| Manufacturer |
Jiangsu Weiming Power Generation Equipment Co., Ltd. |
|
||||||
| Model |
WM 31BG |
Excitation Method |
Brushless Self-Excited (PMG Optional) |
|||||
| Voltage Regulation Range |
≥±5% |
Steady-State Voltage Regulation Rate |
≤±1.0% |
|||||
| Temperature Rise |
H |
Voltage Control Method |
AVR |
|||||
| Insulation Class |
H |
Overload Capacity |
1.5 times for 2 minutes |
|||||
| Protection Class |
IP22 |
Short Circuit Capacity |
3 times for 10 seconds |
|||||
| Efficiency |
91.89% |
Cooling Method |
Self-Cooling |
|||||
| Telephone Interference Coefficient |
THF<2%, TIF<50 |
Rotor Type |
Salient-Pole Type |
|||||
Note: The above technical data is for reference only. Our company will not be held responsible for any changes in technical parameters due to various reasons.